Complementary clinical benefits of coronary-artery stenting and blockade of platelet glycoprotein IIb/IIIa receptors. Evaluation of Platelet IIb/IIIa Inhibition in Stenting Investigators. Academic Article uri icon

Overview

abstract

  • BACKGROUND: Inhibition of the platelet glycoprotein IIb/IIIa receptor with the monoclonal-antibody fragment abciximab reduces the acute ischemic complications associated with percutaneous coronary revascularization, whereas coronary-stent implantation reduces restenosis. We conducted a trial to determine the efficacy of abciximab and stent implantation in improving long-term outcome. METHODS: A total of 2399 patients were randomly assigned to stent implantation and placebo, stent implantation and abciximab, or balloon angioplasty and abciximab. The patients were followed for six months. RESULTS: At six months, the incidence of the composite end point of death or myocardial infarction was 11.4 percent in the group that received a stent and placebo, as compared with 5.6 percent in the group that received a stent and abciximab (hazard ratio, 0.47; 95 percent confidence interval, 0.33 to 0.68; P<0.001) and 7.8 percent in the group assigned to balloon angioplasty and abciximab (hazard ratio, 0.67; 95 percent confidence interval, 0.49 to 0.92; P=0.01). The hazard ratio for stenting plus abciximab as compared with angioplasty plus abciximab was 0.70 (95 percent confidence interval, 0.48 to 1.04; P=0.07). The rate of repeated revascularization of the target vessel was 10.6 percent in the stent-plus-placebo group, as compared with 8.7 percent in the stent-plus-abciximab group (hazard ratio, 0.82; 95 percent confidence interval, 0.59 to 1.13; P=0.22) and 15.4 percent in the angioplasty-plus-abciximab group (hazard ratio, 1.49; 95 percent confidence interval, 1.13 to 1.97; P=0.005). The hazard ratio for stenting plus abciximab as compared with angioplasty plus abciximab was 0.55 (95 percent confidence interval, 0.41 to 0.74; P<0.001). Among patients with diabetes, the combination of abciximab and stenting was associated with a lower rate of repeated target-vessel revascularization (8.1 percent) than was stenting and placebo (16.6 percent, P=0.02) or angioplasty and abciximab (18.4 percent, P=0.008). CONCLUSIONS: For coronary revascularization, abciximab and stent implantation confer complementary long-term clinical benefits.

publication date

  • July 29, 1999

Research

keywords

  • Angioplasty, Balloon, Coronary
  • Antibodies, Monoclonal
  • Coronary Disease
  • Immunoglobulin Fab Fragments
  • Platelet Aggregation Inhibitors
  • Platelet Glycoprotein GPIIb-IIIa Complex
  • Stents

Identity

Scopus Document Identifier

  • 0033615009

PubMed ID

  • 10423466

Additional Document Info

volume

  • 341

issue

  • 5