PCR analysis of the immunoglobulin heavy chain gene in polyclonal processes can yield pseudoclonal bands as an artifact of low B cell number. Academic Article uri icon

Overview

abstract

  • Polymerase chain reaction (PCR)-based analysis for detecting immunoglobulin heavy chain gene (IgH) rearrangements in lymphoproliferative disorders is well established. The presence of one or two discrete bands is interpreted as a monoclonal proliferation, whereas a smear pattern represents a polyclonal population. Prompted by our observation of discrete bands in histologically reactive processes with a relative paucity of B cells, we sought to determine whether low numbers of B cells in biopsy specimens could artifactually produce pseudomonoclonal bands. We performed IgH PCR analysis on serially diluted DNA samples from 5 B cell non-Hodgkin's lymphomas (B-NHLs), 5 reactive lymph nodes, 5 reactive tonsils and 10 microdissected germinal centers from a lymph node with follicular hyperplasia. We also assessed multiple aliquots of DNA samples from small biopsy specimens of reactive lymphocytic processes from the stomach (5 cases). PCR products were evaluated using high resolution agarose or polyacrylamide gels, and DNA sequencing was performed on IgH PCR products from two reactive germinal centers, which yielded monoclonal bands of identical size. All 5 B-NHLs harboring monoclonal B cell populations yielded single discrete bands, which were maintained in all dilutions. By contrast, all of the reactive lesions with polyclonal patterns at 50 ng/microl starting template concentration showed strong pseudomonoclonal bands at dilutions of 1:1,000 to 1:1,500 in placental DNA. Two of the microdissected reactive germinal centers that showed bands of identical size on duplicate reactions were proven to have different IgH sequences by sequencing. We conclude that specimens containing low numbers of polyclonal B cells may produce pseudomonoclonal bands on IgH PCR analysis. IgH PCR analysis should be performed on multiple aliquots of each DNA sample, and only samples that yield reproducible bands of identical size can be reliably interpreted as monoclonal.

publication date

  • May 1, 2000

Research

keywords

  • B-Lymphocytes
  • Genes, Immunoglobulin
  • Immunoglobulin Heavy Chains
  • Polymerase Chain Reaction

Identity

PubMed Central ID

  • PMC1906898

Scopus Document Identifier

  • 0034189489

Digital Object Identifier (DOI)

  • 10.1016/S1525-1578(10)60622-8

PubMed ID

  • 11272894

Additional Document Info

volume

  • 2

issue

  • 2