Two-part and three-part fractures of the proximal humerus treated with suture fixation. Academic Article uri icon

Overview

abstract

  • OBJECTIVE: To evaluate the radiographic and clinical outcomes of patients with displaced proximal humerus fractures (two-part and three-part) treated with nonabsorbable rotator cuff-incorporating sutures. DESIGN: Retrospective. SETTING: University hospital. PATIENTS: There were 27 patients (28 shoulders) with displaced proximal humerus fractures. There were 13 greater tuberosity (GT) and 9 surgical neck (SN) two-part fractures and 6 GT/SN three-part fractures. The average age was 64 years (range 38 to 84 years). The average follow-up was 4.4 years (range 1.0 to 11.5 years). INTERVENTION: All patients were surgically treated solely with heavy polyester nonabsorbable sutures. MAIN OUTCOME MEASUREMENTS: Functional assessment was obtained using the American Shoulder and Elbow Surgeons (ASES) score and Neer's criteria, which grade outcomes as excellent, satisfactory, or unsatisfactory. RESULTS: Overall, there were 22 (78%) excellent, 3 (11%) satisfactory, and 3 (11%) unsatisfactory results, and the average ASES score was 87.1 (range 35.0 to 100.0). All shoulders healed radiographically without evidence of avascular necrosis of the humeral head. Twenty-four shoulders (86%) had anatomic alignment on postoperative radiographs. Of four shoulders with nonanatomic alignment, three had ASES scores of >/=90, with excellent Neer scores. When comparing patients with isolated two-part GT fractures (n = 13) with patients having two-part SN or three-part SN/GT fractures (n = 15), there were no statistically significant differences with respect to range of motion (P > 0.05) and outcome measures (P > 0.05). All patients who had unsatisfactory outcomes were noncompliant with physical therapy, with ASES scores averaging 39.4 (range 35.0 to 43.3). CONCLUSION: Two-part and three-part GT and SN fractures can be treated satisfactorily with heavy nonabsorbable rotator cuff-incorporating sutures, particularly in elderly patients. Hardware-associated complications are obviated. Patients with SN fractures treated with sutures can have outcomes similar to patients with two-part GT fractures. Although the goal is to reconstruct a "one-part" fracture pattern, some residual deformity does not preclude an excellent outcome. A compliant patient is crucial for a successful result.

publication date

  • May 1, 2003

Research

keywords

  • Fracture Fixation, Internal
  • Shoulder Fractures
  • Sutures

Identity

Scopus Document Identifier

  • 0038513423

Digital Object Identifier (DOI)

  • 10.1097/00005131-200305000-00001

PubMed ID

  • 12759635

Additional Document Info

volume

  • 17

issue

  • 5