Histologic and mechanical evaluation of impaction grafting for femoral component revision in a goat model. Academic Article uri icon

Overview

abstract

  • A goat model of revision hip arthroplasty was used to examine the histology and mechanical performance of impaction grafting using two femoral stems varying in stem surface finish. There were no significant mechanical or qualitative histologic differences between smooth, tapered, polished stems and step-cut, grit-blasted stems. Allograft distribution, bone incorporation, and cement mantle thickness were not uniform within the femoral canal. Efforts to improve the impaction grafting technique may be more important than stem design.

publication date

  • January 1, 2005

Research

keywords

  • Arthroplasty, Replacement, Hip
  • Bone Transplantation
  • Hip Prosthesis

Identity

Scopus Document Identifier

  • 12344269171

Digital Object Identifier (DOI)

  • 10.3928/0147-7447-20050101-14

PubMed ID

  • 15682576

Additional Document Info

volume

  • 28

issue

  • 1