Dose as a function of lung volume and planned treatment volume in helical tomotherapy intensity-modulated radiation therapy-based stereotactic body radiation therapy for small lung tumors. Academic Article uri icon

Overview

abstract

  • PURPOSE: To evaluate the limitations of Hi-Art Helical Tomotherapy (Middleton, WI) stereotactic body radiotherapy (SBRT) for lung lesions, and to provide an initial report on patients treated with this method. Stereotactic body radiotherapy was shown to be an effective, well-tolerated treatment for early-stage, non-small-cell lung carcinoma (NSCLC). The Radiation Therapy Oncology Group (RTOG) 0236 protocol is currently evaluating three-dimensional conformal SBRT that delivers 60 Gy in three fractions. METHODS AND MATERIALS: Inverse treatment planning for hypothetical lung gross tumor volumes (GTV) and planned treatment volume (PTV) expansions were performed. We tested the hypothesis that the maximum acceptable dose (MAD) to be delivered to the lesion by SBRT could be predicted by PTV and lung volume. Dose constraints on normal tissue were as designated by the RTOG protocol. Inverse planning was performed to find the maximum tolerated SBRT dose up to 60 Gy. RESULTS: Regression analysis of the data obtained indicated a linear relationship between MAD, PTV, and lung volume. This generated two equations which may be useful predictive tools. Seven patients with Stage I and II NSCLC treated at the University of Virginia with this method tolerated the treatment extremely well, and suffered no greater than grade I toxicity, with no evidence of disease recurrence in follow-up from 2-20 months. CONCLUSIONS: Helical tomotherapy SBRT for lung lesions is well-tolerated. In addition, the likely MAD for patients considered for this type of treatment can be predicted by PTV and lung volume.

publication date

  • May 21, 2007

Research

keywords

  • Carcinoma, Non-Small-Cell Lung
  • Lung Neoplasms
  • Radiotherapy, Intensity-Modulated

Identity

Scopus Document Identifier

  • 34447272246

PubMed ID

  • 17513066

Additional Document Info

volume

  • 68

issue

  • 4