Comparison of isometric and anatomic reconstruction of the medial patellofemoral ligament: a cadaveric study. Academic Article uri icon

Overview

abstract

  • Recent surgical procedures designed to correct recurrent posttraumatic lateral patellar instability focus on reconstructing the medial patellofemoral ligament. This study evaluated and compared patellofemoral kinematics of isometric and anatomic medial patellofemoral ligament reconstructions. Using an infrared motion capture analysis system, patellar tracking was evaluated in the coronal plane in 6 cadaveric specimens. Reconstruction of the medial patellofemoral ligament using an isometric technique did not restore normal patellar tracking at any flexion angle; however, reconstruction using an anatomic technique restored statistically normal patellar tracking from maximal knee extension to 28 degrees of flexion. Neither technique was able to restore normal kinematics in deeper angles of knee flexion.

publication date

  • April 1, 2008

Research

keywords

  • Models, Anatomic
  • Orthopedic Procedures
  • Patellar Dislocation
  • Patellar Ligament
  • Plastic Surgery Procedures
  • Reconstructive Surgical Procedures

Identity

Scopus Document Identifier

  • 44349180285

Digital Object Identifier (DOI)

  • 10.3928/01477447-20080401-28

PubMed ID

  • 18453169

Additional Document Info

volume

  • 31

issue

  • 4