Comparison of velocity patterns in an AComA aneurysm measured with 2D phase contrast MRI and simulated with CFD. Academic Article uri icon

Overview

abstract

  • OBJECTIVE: Computational Fluid Dynamic (CFD) is increasingly being used for modeling hemodynamics in intracranial aneurysms. While CFD techniques are well established, need for validation of the results remains. By quantifying features in velocity patterns measured with 2D phase contrast magnetic resonance (pcMRI) in vivo and simulated with CFD, the role of pcMRI for providing reference data for the CFD simulation is explored. METHODS: Unsteady CFD simulations were performed with inflow boundary conditions obtained from 2D pcMRI measurements of an aneurysm of the anterior communication artery. Intra-aneurysmal velocity profiles were recorded with 2D pcMRI and calculated with CFD. Relative areas of positive and negative velocity were calculated in these profiles for maximum and minimum inflow. RESULTS: Areas of positive and of negative velocity similar in shape were found in the velocity profiles obtained with both methods. Relative difference in size of the relative areas for the whole cardiac cycle ranged from 1%-25% (average 12%). CONCLUSION: 2D pcMRI is able to record velocity profiles in an aneurysm of the anterior commuting artery in vivo. These velocity profiles can serve as reference data for validation of CFD simulations. Further studies are needed to explore the role of pcMRI in the context of CFD simulations.

publication date

  • January 1, 2008

Research

keywords

  • Computer Simulation
  • Intracranial Aneurysm

Identity

Scopus Document Identifier

  • 47849110068

PubMed ID

  • 18487858

Additional Document Info

volume

  • 16

issue

  • 2