Somatosensory evoked potential monitoring in the surgical management of acute acetabular fractures. Academic Article uri icon

Overview

abstract

  • Fifty patients undergoing acute acetabular fracture surgery had intraoperative somatosensory evoked potential (SSEP) monitoring. Group II, the final 38 patients, in addition had independent neurological evaluation preoperatively and postoperatively. Thirteen of 50 patients (26%) had preoperative sciatic nerve involvement. Fourteen of 50 patients (28%) developed significant intraoperative SSEP changes (decreased amplitude, increased latency). When the nerve was involved preoperatively (high-risk group), changes in SSEP occurred in 60% of patients. Iatrogenic sciatic/peroneal neuropraxia occurred in only one patient in the series (2%), and this resolved within 4 months. These results compare favorably to the incidence of 5-18% reported in the literature. We conclude SSEP is feasible and should be used in the operative treatment of acetabular fractures, especially the posterior fracture patterns and for those in the high-risk group.

publication date

  • January 1, 1991

Research

keywords

  • Acetabulum
  • Evoked Potentials, Somatosensory
  • Fractures, Bone
  • Intraoperative Complications
  • Peroneal Nerve
  • Sciatic Nerve

Identity

Scopus Document Identifier

  • 0025983601

PubMed ID

  • 1861191

Additional Document Info

volume

  • 5

issue

  • 2