Radiosynthesis of [(131)I]IAZGP via nucleophilic substitution and its biological evaluation as a hypoxia marker - is specific activity a factor influencing hypoxia-mapping ability of a hypoxia marker? Academic Article uri icon

Overview

abstract

  • INTRODUCTION: The hypoxia marker IAZGP, 1-(6-deoxy-6-iodo-beta-d-galactopyranosyl)-2-nitroimidazole, has been labeled with (123)I/(124)I/(125)I/(131)I via iodine-radioiodine exchange, which gives the radiotracer in a specific activity of 10-90 MBq/micromol. We synthesized the same radiotracer possessing several hundred to thousand times higher specific activity (high-SA IAZGP) via nucleophilic substitution and compared its biological behavior with that of conventionally produced IAZGP (low-SA IAZGP) to determine if specific activity is a factor influencing cell uptake kinetics, biodistribution and intratumor microregional localization of the radiotracer. METHODS: High-SA [(131)I]IAZGP was prepared by substitution of the tosyl functionality with [(131)I]iodide. In vitro uptake of high- and low-SA [(131)I]IAZGP by HCT8 and HT29 cells was assessed in normoxic and hypoxic conditions. Biodistribution and intratumor localization of high- and low-SA [(131)I]IAZGP were determined by injection into HT29 tumor-bearing mice. RESULTS: The nucleophilic substitution reaction proceeded efficiently in acetonitrile at 150 degrees C, giving the final product in an average yield of 42% and an average specific activity of 30 GBq/micromol. In vitro, high-SA [(131)I]IAZGP was incorporated into the tumor cells with similar kinetics and oxygen dependence to low-SA [(131)I]IAZGP. In HT29 tumor-bearing mice, biodistributions of high- and low-SA [(131)I]IAZGP were equivalent. Ex vivo autoradiography revealed heterogeneous intratumor localization of high-SA [(131)I]IAZGP corresponding closely to distributions of other exogenous and endogenous hypoxia markers. Comparable microregional distribution patterns were observed with low-SA [(131)I]IAZGP. CONCLUSIONS: Radiolabeled IAZGP produced via nucleophilic substitution is validated as an exogenous hypoxia marker. Specific activity does not appear to influence the in vivo hypoxia-mapping ability of the radiotracer.

publication date

  • May 7, 2009

Research

keywords

  • Cell Hypoxia
  • Galactosides
  • Nitroimidazoles

Identity

PubMed Central ID

  • PMC2837594

Scopus Document Identifier

  • 67349256741

Digital Object Identifier (DOI)

  • 10.1016/j.nucmedbio.2009.03.002

PubMed ID

  • 19520288

Additional Document Info

volume

  • 36

issue

  • 5