Quantification of muscle fat in patients with low back pain: comparison of multi-echo MR imaging with single-voxel MR spectroscopy. Academic Article uri icon

Overview

abstract

  • PURPOSE: To compare lumbar muscle fat-signal fractions derived from three-dimensional dual gradient-echo magnetic resonance (MR) imaging and multiple gradient-echo MR imaging with fractions from single-voxel MR spectroscopy in patients with low back pain. MATERIALS AND METHODS: This prospective study had institutional review board approval, and written informed consent was obtained from all study participants. Fifty-six patients (32 women; mean age, 52 years ± 15 [standard deviation]; age range, 20-79 years) with low back pain underwent standard 1.5-T MR imaging, which was supplemented by dual-echo MR imaging, multi-echo MR imaging, and MR spectroscopy to quantify fatty degeneration of bilateral lumbar multifidus muscles in a region of interest at the intervertebral level of L4 through L5. Fat-signal fractions were determined from signal intensities on fat- and water-only images from both imaging data sets (dual-echo and multi-echo fat-signal fractions without T2* correction) or directly obtained, with additional T2* correction, from multi-echo MR imaging. The results were compared with MR spectroscopic fractions. The Student t test and Bland-Altman plots were used to quantify agreement between fat-signal fractions derived from imaging and from spectroscopy. RESULTS: In total, 102 spectroscopic measurements were obtained bilaterally (46 of 56) or unilaterally (10 of 56). Mean spectroscopic fat-signal fraction was 19.6 ± 11.4 (range, 5.4-63.5). Correlation between spectroscopic and all imaging-based fat-signal fractions was statistically significant (R(2) = 0.87-0.92; all P < .001). Mean dual-echo fat-signal fractions not corrected for T2* and multi-echo fat-signal fractions corrected for T2* significantly differed from spectroscopic fractions (both P < .01), but mean multi-echo fractions not corrected for T2* did not (P = .11). There was a small measurement bias of 0.5% (95% limits of agreement: -6.0%, 7.2%) compared with spectroscopic fractions. CONCLUSION: Large-volume image-based (dual-echo and multi-echo MR imaging) and spectroscopic fat-signal fractions agree well, thus allowing fast and accurate quantification of muscle fat content in patients with low back pain.

publication date

  • November 9, 2012

Research

keywords

  • Adipose Tissue
  • Low Back Pain
  • Magnetic Resonance Spectroscopy
  • Muscle, Skeletal

Identity

Scopus Document Identifier

  • 84873404384

Digital Object Identifier (DOI)

  • 10.1148/radiol.12120399

PubMed ID

  • 23143025

Additional Document Info

volume

  • 266

issue

  • 2