Geometry-independent inclusion of basal myocardium yields improved cardiac magnetic resonance agreement with echocardiography and necropsy quantified left-ventricular mass. Academic Article uri icon

Overview

abstract

  • OBJECTIVES: Left-ventricular mass (LVM) is widely used to guide clinical decision-making. Cardiac magnetic resonance (CMR) quantifies LVM by planimetry of contiguous short-axis images, an approach dependent on reader-selection of images to be contoured. Established methods have applied different binary cut-offs using circumferential extent of left-ventricular myocardium to define the basal left ventricle (LV), omitting images containing lesser fractions of left-ventricular myocardium. This study tested impact of basal slice variability on LVM quantification. METHODS: CMR was performed in patients and laboratory animals. LVM was quantified with full inclusion of left-ventricular myocardium, and by established methods that use different cut-offs to define the left-ventricular basal-most slice: 50% circumferential myocardium at end diastole alone (ED50), 50% circumferential myocardium throughout both end diastole and end systole (EDS50). RESULTS: One hundred and fifty patients and 10 lab animals were studied. Among patients, fully inclusive LVM (172.6±42.3g) was higher vs. ED50 (167.2±41.8g) and EDS50 (150.6±41.1g; both P<0.001). Methodological differences yielded discrepancies regarding proportion of patients meeting established criteria for left-ventricular hypertrophy and chamber dilation (P<0.05). Fully inclusive LVM yielded smaller differences with echocardiography (Δ=11.0±28.8g) than did ED50 (Δ=16.4±29.1g) and EDS50 (Δ=33.2±28.7g; both P<0.001). Among lab animals, ex-vivo left-ventricular weight (69.8±13.2g) was similar to LVM calculated using fully inclusive (70.1±13.5g, P=0.67) and ED50 (69.4±13.9g; P=0.70) methods, whereas EDS50 differed significantly (67.9±14.9g; P=0.04). CONCLUSION: Established CMR methods that discordantly define the basal-most LV produce significant differences in calculated LVM. Fully inclusive quantification, rather than binary cut-offs that omit basal left-ventricular myocardium, yields smallest CMR discrepancy with echocardiography-measured LVM and non-significant differences with necropsy-measured left-ventricular weight.

publication date

  • October 1, 2013

Research

keywords

  • Heart Ventricles
  • Hypertrophy, Left Ventricular
  • Magnetic Resonance Imaging
  • Myocardial Infarction
  • Myocardium

Identity

PubMed Central ID

  • PMC4017912

Scopus Document Identifier

  • 84884362204

Digital Object Identifier (DOI)

  • 10.1097/HJH.0b013e328362d935

PubMed ID

  • 24107735

Additional Document Info

volume

  • 31

issue

  • 10