Impact of dose to the bladder trigone on long-term urinary function after high-dose intensity modulated radiation therapy for localized prostate cancer. Academic Article uri icon

Overview

abstract

  • PURPOSE: To determine the potential association between genitourinary (GU) toxicity and planning dose-volume parameters for GU pelvic structures after high-dose intensity modulated radiation therapy in localized prostate cancer patients. METHODS AND MATERIALS: A total of 268 patients who underwent intensity modulated radiation therapy to a prescribed dose of 86.4 Gy in 48 fractions during June 2004-December 2008 were evaluated with the International Prostate Symptom Score (IPSS) questionnaire. Dose-volume histograms of the whole bladder, bladder wall, urethra, and bladder trigone were analyzed. The primary endpoint for GU toxicity was an IPSS sum increase ≥10 points over baseline. Univariate and multivariate analyses were done by the Kaplan-Meier method and Cox proportional hazard models, respectively. RESULTS: Median follow-up was 5 years (range, 3-7.7 years). Thirty-nine patients experienced an IPSS sum increase ≥10 during follow-up; 84% remained event free at 5 years. After univariate analysis, lower baseline IPSS sum (P=.006), the V90 of the trigone (P=.006), and the maximal dose to the trigone (P=.003) were significantly associated with an IPSS sum increase ≥10. After multivariate analysis, lower baseline IPSS sum (P=.009) and increased maximal dose to the trigone (P=.005) remained significantly associated. Seventy-two patients had both a lower baseline IPSS sum and a higher maximal dose to the trigone and were defined as high risk, and 68 patients had both a higher baseline IPSS sum and a lower maximal dose to the trigone and were defined as low risk for development of an IPSS sum increase ≥10. Twenty-one of 72 high-risk patients (29%) and 5 of 68 low-risk patients (7%) experienced an IPSS sum increase ≥10 (P=.001; odds ratio 5.19). CONCLUSIONS: The application of hot spots to the bladder trigone was significantly associated with relevant changes in IPSS during follow-up. Reduction of radiation dose to the lower bladder and specifically the bladder trigone seems to be associated with a reduction in late GU toxicity.

publication date

  • February 1, 2014

Research

keywords

  • Organs at Risk
  • Prostatic Neoplasms
  • Radiation Injuries
  • Radiotherapy, Intensity-Modulated
  • Urinary Bladder
  • Urogenital System

Identity

PubMed Central ID

  • PMC4581453

Scopus Document Identifier

  • 84891856300

Digital Object Identifier (DOI)

  • 10.1016/j.ijrobp.2013.10.042

PubMed ID

  • 24411606

Additional Document Info

volume

  • 88

issue

  • 2