Vertebral body Hounsfield units as a predictor of incidental durotomy in primary lumbar spinal surgery. Academic Article uri icon

Overview

abstract

  • STUDY DESIGN: Retrospective cohort study. OBJECTIVE: To assess the association between vertebral body Hounsfield unit (HU) measurements on quantitative computed tomography and the risk for incidental durotomy (ID). SUMMARY OF BACKGROUND DATA: ID during spine surgery has been associated with adverse postoperative sequelae that may require prolonged hospital stay and reoperation. Previously identified independent risk factors include age, revision surgery, and lumbar surgery. METHODS: ID was prospectively documented in spine surgery patients at a single institution during a 2-year period (incidence: 4%, 191/4,822). Patients with ID were matched 1:1 to a control cohort without ID based on age and sex. Inclusion criteria for both cohorts were primary lumbar surgery and quantitative computed tomographic scans within 1 year of date of surgery. Demographic, radiographical, and intraoperative data, along with dual x-ray absorptiometry t scores, were collected and analyzed. RESULTS: A total of 71 patients with ID met the inclusion criteria (38 male, 33 female). Average age of patients with ID was 63.8 ± 12.9 years (range: 34-85 yr). Computed tomographic scans were acquired 1.5 ± 2.2 months away from date of surgery (range: 0-12 mo). Inter-rater reliability for HU measurements between a fellowship-trained spine surgeon and a research fellow was strong (r = 0.901, P < 0.001). HU values were significantly lower in patients with ID than controls (149.2 ± 60.7 [range: 44.5-301.5] versus 177.0 ± 81.4, [range: 62.0-524.0], respectively; P = 0.023). The area under the receiver operating characteristic curve was 0.603 (P = 0.034). A threshold of 169 HU optimized sensitivity (0.718) and specificity (0.451), and patients with HU value 169 or less were found to be at increased risk for ID (odds ratio: 2.092, 95% confidence interval: 1.042-4.201, P = 0.037). CONCLUSION: Lower HU value is an accessible clinical marker for increased risk of ID. A threshold value of HU was defined (≤169) that may be used clinically to identify patients at elevated risk for ID, which may improve the informed decision making process prior to spinal surgery. LEVEL OF EVIDENCE: 3.

publication date

  • April 20, 2014

Research

keywords

  • Dura Mater
  • Intraoperative Complications
  • Lumbar Vertebrae
  • Lumbosacral Region
  • Orthopedic Procedures

Identity

Scopus Document Identifier

  • 84899648983

Digital Object Identifier (DOI)

  • 10.1097/BRS.0000000000000255

PubMed ID

  • 24503684

Additional Document Info

volume

  • 39

issue

  • 9