Scoring system to guide decision making for the use of gentamicin-impregnated collagen sponge to prevent deep sternal wound infection.
Academic Article
Overview
abstract
OBJECTIVES: The effectiveness of the routine retrosternal placement of a gentamicin-impregnated collagen sponge (GICS) implant before sternotomy closure is currently a matter of some controversy. We aimed to develop a scoring system to guide decision making for the use of GICS to prevent deep sternal wound infection. METHODS: Fast backward elimination on predictors, including GICS, was performed using the Lawless and Singhal method. The scoring system was reported as a partial nomogram that can be used to manually obtain predicted individual risk of deep sternal wound infection from the regression model. Bootstrapping validation of the regression models was performed. RESULTS: The final populations consisted of 8750 adult patients undergoing cardiac surgery through full sternotomy during the study period. A total of 329 patients (3.8%) received GICS implant. The overall incidence of deep sternal wound infection was lower among patients who received GICS implant (0.6%) than patients who did not (2.01%) (P=.02). A nomogram to predict the individual risk for deep sternal wound infection was developed that included the use of GICS. Bootstrapping validation confirmed a good discriminative power of the models. CONCLUSIONS: The scoring system provides an impartial assessment of the decision-making process for clinicians to establish if GICS implant is effective in reducing the risk for deep sternal wound infection in individual patients undergoing cardiac surgery through full sternotomy.