Deciphering lipid structures based on platform-independent decision rules. Academic Article uri icon

Overview

abstract

  • We achieve automated and reliable annotation of lipid species and their molecular structures in high-throughput data from chromatography-coupled tandem mass spectrometry using decision rule sets embedded in Lipid Data Analyzer (LDA; http://genome.tugraz.at/lda2). Using various low- and high-resolution mass spectrometry instruments with several collision energies, we proved the method's platform independence. We propose that the software's reliability, flexibility, and ability to identify novel lipid molecular species may now render current state-of-the-art lipid libraries obsolete.

publication date

  • October 23, 2017

Research

keywords

  • Chromatography, Liquid
  • Lipids
  • Tandem Mass Spectrometry

Identity

PubMed Central ID

  • PMC5988032

Scopus Document Identifier

  • 85034778000

Digital Object Identifier (DOI)

  • 10.1038/nmeth.4470

PubMed ID

  • 29058722

Additional Document Info

volume

  • 14

issue

  • 12