Frequency and phase correction for multiplexed edited MRS of GABA and glutathione.
        Academic Article
                     
                
        
                
            
    
    
        
         
     
    
    
    
        
        
            Overview
			
            
        
        		
        		
            	
                abstract   
                
            
    
        	
                
    
    
    
			    
    	
	    -     
    	PURPOSE: Detection of endogenous metabolites using multiplexed editing substantially improves the efficiency of edited magnetic resonance spectroscopy. Multiplexed editing (i.e., performing more than one edited experiment in a single acquisition) requires a tailored, robust approach for correction of frequency and phase offsets. Here, a novel method for frequency and phase correction (FPC) based on spectral registration is presented and compared against previously presented approaches. METHODS: One simulated dataset and 40 γ-aminobutyric acid-/glutathione-edited HERMES datasets acquired in vivo at three imaging centers were used to test four FPC approaches: no correction; spectral registration; spectral registration with post hoc choline-creatine alignment; and multistep FPC. The performance of each routine for the simulated dataset was assessed by comparing the estimated frequency/phase offsets against the known values, whereas the performance for the in vivo data was assessed quantitatively by calculation of an alignment quality metric based on choline subtraction artifacts. RESULTS: The multistep FPC approach returned corrections that were closest to the true values for the simulated dataset. Alignment quality scores were on average worst for no correction, and best for multistep FPC in both the γ-aminobutyric acid- and glutathione-edited spectra in the in vivo data. CONCLUSIONS: Multistep FPC results in improved correction of frequency/phase errors in multiplexed γ-aminobutyric acid-/glutathione-edited magnetic resonance spectroscopy experiments. The optimal FPC strategy is experiment-specific, and may even be dataset-specific. Magn Reson Med 80:21-28, 2018. © 2017 International Society for Magnetic Resonance in Medicine. 
	    
publication date   
                
            
    
        	
                
	             
 
        
        		
        		
            	
                published in   
                
            
    
        	
                
	             
 
        
        
         
    
    
        
        
            Research
			
            
        
        		
        		
            	
                keywords   
                
            
    
        	
                
    
    
    
			    
    	
	    -     
    	Brain 
	    
-     
    	Glutathione 
	    
-     
    	Magnetic Resonance Spectroscopy 
	    
-     
    	gamma-Aminobutyric Acid 
	    
Identity
			
            
        
        		
        		
            	
                PubMed Central ID   
                
            
    
        	
                
	             
 
        
        		
        		
            	
                Scopus Document Identifier   
                
            
    
        	
                
	             
 
        
        		
        		
            	
                Digital Object Identifier (DOI)   
                
            
    
        	
                
	             
 
        
        		
        		
            	
                PubMed ID   
                
            
    
        	
                
	             
 
        
        
         
    
    
        
        
            Additional Document Info
			
            
        
        		
        		
            	
                has global citation frequency   
                
            
    
        	
                
	             
 
        
        		
        		
            	
                volume   
                
            
    
        	
                
	             
 
        
        		
        		
            	
                issue