Arthroscopic Diagnosis of the Triangular Fibrocartilage Complex Foveal Tear: A Cadaver Assessment. Academic Article uri icon

Overview

abstract

  • PURPOSE: To determine whether the arthroscopic hook and trampoline tests are accurate and reliable diagnostic tests for foveal triangular fibrocartilage complex (TFCC) detachment. METHODS: Wrist arthroscopy was performed on 10 cadaveric upper extremities. Arthroscopic hook and trampoline tests were performed and videos recorded (baseline). The deep foveal TFCC insertion was then sharply detached. Arthroscopic hook and trampoline tests were repeated. Subsequently, the foveal detachment was repaired via an ulnar tunnel technique and the hook test was repeated for a third time. Videos were independently reviewed at 2 time points by 2 fellowship-trained hand surgeons and 1 hand surgery fellow in a randomized and blinded fashion. Hook and trampoline tests were graded as positive or negative. Proportions of categorical variables were compared via 2-tailed Fisher exact test. Inter- and intraobserver reliabilities were assessed via Cohen kappa coefficient. RESULTS: The sensitivity and specificity of the hook test for foveal detachment diagnosis were 90% and 90%, respectively. There was 90% agreement among all 3 observers for the baseline and foveal detachment hook tests. Cohen kappa coefficients for the inter- and intraobserver reliabilities of the hook test were 0.87 and 0.81, respectively. Seventeen percent of trampoline tests were positive at baseline versus 43% after foveal detachment. The trampoline test had 45% agreement between the 3 observers. Cohen kappa coefficients for the inter- and intraobserver reliabilities of the trampoline test were 0.16 and 0.63, respectively. Following ulnar tunnel repair, 20% of hook tests were positive. CONCLUSIONS: The hook test is highly sensitive, specific, and reliable for the diagnosis of isolated TFCC foveal detachment. The trampoline test has insufficient reliability to assess foveal detachment. A TFCC foveal repair using an ulnar tunnel technique returns the hook test to baseline. CLINICAL RELEVANCE: The hook test is a sensitive, specific, and reliable test for the diagnosis of isolated TFCC foveal detachment.

publication date

  • February 1, 2018

Research

keywords

  • Arthroscopy
  • Triangular Fibrocartilage
  • Wrist Injuries

Identity

Scopus Document Identifier

  • 85041583659

Digital Object Identifier (DOI)

  • 10.1016/j.jhsa.2017.12.017

PubMed ID

  • 29395584

Additional Document Info

volume

  • 43

issue

  • 7