Language mapping using electrocorticography versus stereoelectroencephalography: A case series. Academic Article uri icon

Overview

abstract

  • Direct electrical stimulation (DES) is sometimes used in epilepsy surgery to identify areas that may result in language deficits if resected. Extraoperative language mapping is usually performed using electrocorticography (ECOG) - grids and strip electrodes; however, given the better safety profile of stereoelectroencephalogaphy (SEEG), it would be desirable to determine if mapping using SEEG is also effective. We report a case series of fifteen patients that underwent language mapping with either ECOG (5), SEEG (9), or both (1). Six patients in the SEEG group underwent resection or ablation with only mapping via SEEG. No patients in the SEEG group that underwent resective or ablative surgery experienced persistent language deficits. These results suggest that language mapping with SEEG may be considered as a clinically useful alternative to language mapping with ECOG.

publication date

  • May 26, 2018

Research

keywords

  • Brain Mapping
  • Electrocorticography
  • Electroencephalography
  • Epilepsy
  • Language

Identity

PubMed Central ID

  • PMC8252889

Scopus Document Identifier

  • 85047245123

Digital Object Identifier (DOI)

  • 10.1016/j.yebeh.2018.04.032

PubMed ID

  • 29803145

Additional Document Info

volume

  • 84