Improved Cancer Detection Using Artificial Intelligence: a Retrospective Evaluation of Missed Cancers on Mammography. Academic Article uri icon

Overview

abstract

  • To determine whether cmAssistâ„¢, an artificial intelligence-based computer-aided detection (AI-CAD) algorithm, can be used to improve radiologists' sensitivity in breast cancer screening and detection. A blinded retrospective study was performed with a panel of seven radiologists using a cancer-enriched data set from 122 patients that included 90 false-negative mammograms obtained up to 5.8 years prior to diagnosis and 32 BIRADS 1 and 2 patients with a 2-year follow-up of negative diagnosis. The mammograms were performed between February 7, 2008 (earliest) and January 8, 2016 (latest), and were all originally interpreted as negative in conjunction with R2 ImageChecker CAD, version 10.0. In this study, the readers analyzed the 122 studies before and after review of cmAssistâ„¢, an AI-CAD software for mammography. The statistical significance of our findings was evaluated using Student's t test and bootstrap statistical analysis. There was a substantial and significant improvement in radiologist accuracy with use of cmAssist, as demonstrated in the 7.2% increase in the area-under-the-curve (AUC) of the receiver operating characteristic (ROC) curve with two-sided p value < 0.01 for the reader group. All radiologists showed a significant improvement in their cancer detection rate (CDR) with the use of cmAssist (two-sided p value = 0.030, confidence interval = 95%). The readers detected between 25 and 71% (mean 51%) of the early cancers without assistance. With cmAssist, the overall reader CDR was 41 to 76% (mean 62%). The percentage increase in CDR for the reader panel was significant, ranging from 6 to 64% (mean 27%) with the use of cmAssist. There was less than 1% increase in the readers' false-positive recalls with use of cmAssist. With the use of cmAssist TM, there was a substantial and statistically significant improvement in radiologists' accuracy and sensitivity for detection of cancers that were originally missed. The percentage increase in CDR for the radiologists in the reader panel ranged from 6 to 64% (mean 27%) with the use of cmAssist, with negligible increase in false-positive recalls.

publication date

  • August 1, 2019

Research

keywords

  • Artificial Intelligence
  • Breast Neoplasms
  • Mammography
  • Radiographic Image Interpretation, Computer-Assisted

Identity

PubMed Central ID

  • PMC6646649

Scopus Document Identifier

  • 85064706920

Digital Object Identifier (DOI)

  • 10.1007/s10278-019-00192-5

PubMed ID

  • 31011956

Additional Document Info

volume

  • 32

issue

  • 4