Novel Anatomic Predictors of New Persistent Left Bundle Branch Block After Evolut Transcatheter Aortic Valve Implantation. Academic Article uri icon

Overview

abstract

  • New persistent left bundle branch block (NP-LBBB) has been associated with adverse outcomes after TAVI but few predictors thus far reported. We sought to identify predictors of NP-LBBB after TAVI with EvolutR/PRO (ER/EP). From 1/2016 to 4/2019, 544 patients from 2 centers underwent TAVI with Evolut (54% ER, 46% EP) for severe native aortic stenosis. Patients with previous LBBB and pacemaker were excluded. Aortic root analysis was performed using 3Mensio Valves Software and membranous septal length (MSL) was determined using the standard coronal view. Clinical, anatomic and procedural characteristics of 396 Evolut were analyzed and predictors of NP-LBBB were identified. Valve Academic Research Consortium-2 outcomes were reported. At discharge, NP-LBBB was seen in 76(19.2%) patients. NP-LBBB in Evolut was associated with implant depth at left coronary cusp (p = 0.004) and 34 mm ER (p = 0.026). Independent predictors of NP-LBBB in Evolut were shorter MSL (odds ratio [OR] = 0.82 per mm septum, 95% confidence interval [CI] = 0.68 to 0.98,p = 0.030), left ventricular outflow tract (LVOT) eccentricity (OR = 1.04 per %, 95% CI = 1.01 to 1.06,p = 0.002), implant depth at noncoronary cusp (NCC) (OR = 1.28 per mm ventricular, 95% CI = 1.11 to 1.48,p = 0.001) and annular perimeter oversizing ≥20% (OR = 2.38, 95% CI = 1.20 to 4.72, p = 0.013). On ROC curve analysis, MSL ≤6.5 mm, NCC depth ≥3 mm and LVOT eccentricity ≥35% were optimal threshold values to predict NP-LBBB. In Conclusion, shorter MSL, LVOT eccentricity, annular oversizing and deeper implant depth are novel predictors of NP-LBBB in Evolut TAVI. Preprocedural CT assessment of aortic root anatomy may help identify patients at risk for NP-LBBB. In such patients, modifying procedural factors such as higher implant and less annular oversizing may reduce the risk of NP-LBBB. Further evaluation of our hypothesis is warranted.

publication date

  • January 30, 2020

Research

keywords

  • Aortic Valve
  • Aortic Valve Stenosis
  • Bundle-Branch Block
  • Heart Ventricles
  • Postoperative Complications
  • Transcatheter Aortic Valve Replacement
  • Ventricular Septum

Identity

Scopus Document Identifier

  • 85079875407

Digital Object Identifier (DOI)

  • 10.1016/j.amjcard.2020.01.008

PubMed ID

  • 32093955

Additional Document Info

volume

  • 125

issue

  • 8