Stiffness After Total Knee Arthroplasty: Is It a Result of Spinal Deformity?
Academic Article
Overview
abstract
BACKGROUND: There are no studies to date analyzing the effect of spinal malalignment on outcomes of total knee arthroplasty (TKA). Knee flexion is a well-described lower extremity compensatory mechanism for maintaining sagittal balance with increasing spinal deformity. The purpose of this study was to determine whether a subset of patients with poor range of motion (ROM) after TKA have unrecognized spinal deformity, predisposing them to knee flexion contractures and stiffness. METHODS: We retrospectively evaluated a consecutive series of patients who underwent manipulation under anesthesia (MUA) for poor ROM after TKA. Using standing full-length biplanar images, knee alignment and spinopelvic parameters were measured. Patients were stratified by pelvic incidence minus lumbar lordosis as a measure of spinal sagittal alignment with a mismatch of ≥10° defined as abnormal, and we calculated the incidence of sagittal spinal deformity. RESULTS: Average ROM before MUA was extension 3° and flexion 83°. About 62% of patients had a pelvic incidence minus lumbar lordosis mismatch of ≥10°. In the spinal deformity group, post-MUA ROM was improved for flexion only, whereas both flexion and extension were improved in the nondeformity group. CONCLUSION: Compensatory knee flexion because of sagittal spinal deformity may predispose to poor ROM after TKA. Patients with clinical suspicion should be worked up preoperatively and counseled accordingly.