  • PURPOSE OF REVIEW: Expanded indications for reverse total shoulder arthroplasty (RSA) have raised awareness of associated complications, including periprosthetic fractures. The purpose of this article was to provide a comprehensive update on how, when, and why RSA-related periprosthetic fractures occur, as well as to describe the current treatment strategies. RECENT FINDINGS: Periprosthetic acromial and scapular spine fractures occur in up to 4.3% of cases and periprosthetic humeral fractures occur in approximately 3.5% of RSA procedures. Fractures of the coracoid process and clavicle have also been reported. Current literature has identified several risk factors for intraoperative or postoperative fracture, including underlying osteoporosis, revision arthroplasty, use of a superiorly placed screw during metaglene fixation, and disruption of the scapular ring by transection of the coracoacromial ligament. Periprosthetic fracture associated with RSA is a clinically significant event that warrants prolonged postoperative vigilance, timely diagnosis, and shared patient decision-making regarding treatment. Further research is needed to identify optimal treatment strategies and characterize long-term clinical outcomes following RSA-related periprosthetic fracture.