A pilot study of 13N-ammonia cardiac PET imaging to assess subacute cardiotoxicity following adjuvant intensity-modulated radiotherapy for locally advanced breast cancer. Academic Article uri icon

Overview

abstract

  • OBJECTIVE: (1) Assess the feasibility of 13 N-ammonia cardiac PET (13 N-ammonia-PET) imaging in radiotherapy (RT) treatment position in locally-advanced breast cancer (LABC) patients. (2) Correlate pre-/post-RT changes in myocardial flow reserve (MFR) with the corresponding radiation heart dose. METHODS: Ten left-sided LABC patients undergoing Volumetric Modulated-Arc-Therapy (VMAT) to chest wall and regional lymph nodes underwent a rest/stress 13 N-ammonia-PET at baseline and (median) 13 months post-RT. Changes in cardiac functions and coronary artery Ca2+ scoring between baseline and follow-up were correlated with average RT dose to the myocardium,3 coronary territories, and 17 myocardial segments. RESULTS: Eight (of 10) patients successfully completed the study. The average rest (stress) global MBF (ml.g-1.min-1) for baseline (follow-up) were 0.83 ± 0.25 (2.4 ± 0.79) and 0.92 ± 0.30 (2.76 ± 0.71), respectively. Differences in MBF, heart rate, blood pressure, and rate-pressure product (RPP) between baseline and follow-up were insignificant (P > 0.1).Strong (R = 0.79; P < 0.01) and moderate (R = 0.53; P = 0.37) correlation existed between MBF Rest and MBF Stress, and RPP respectively. Four patients showed a reduction in MFR of up to ~41% in follow-up studies, increasing to ~52% in myocardial segments close to high-radiation isodose lines in 5/8 patients. Agatston Ca + 2 scoring were zero in both baseline and follow-up in six patients; two patients exhibited mild increase in Ca + 2 on follow-ups (range:10-20).Rest and stress LVEF's were normal (>50) for all patients in both studies. CONCLUSION: The feasibility of 13 N-ammonia-PET imaging in treatment position of LABC patients was demonstrated. MFR at 1-year post-irradiation of the heart decreased in 50% of the patients. MFR may be a potential index for early detection of cardiotoxicity in BC patients receiving RT to the chest wall.

authors

  • Nehmeh, Sadek
  • Fox, Joseph J
  • Schwartz, Jazmin
  • Ballangrud, Åse M
  • Schöder, Heiko
  • Zhao, Yize
  • Strauss, Henry W
  • Yu, Anthony
  • Gupta, Dipti
  • Powell, Simon N
  • Ho, Alice Y

publication date

  • August 27, 2020

Research

keywords

  • Breast Neoplasms
  • Radiotherapy, Intensity-Modulated

Identity

PubMed Central ID

  • PMC8207896

Scopus Document Identifier

  • 85090321994

Digital Object Identifier (DOI)

  • 10.1016/j.clinimag.2020.07.026

PubMed ID

  • 32919154

Additional Document Info

volume

  • 68