Low-frequency avoidable errors during transcarotid artery revascularization. Academic Article uri icon

Overview

abstract

  • OBJECTIVE: Transcarotid artery revascularization (TCAR) seems to be a safe and effective alternative to carotid endarterectomy (CEA) and transfemoral carotid artery stenting (TF-CAS). The TCAR system represents a paradigm shift in the management of carotid artery stenosis with potential for a significant decrease in periprocedural morbidity. However, as with CEA or TF-CAS, TCAR is associated with infrequent complications related to user technical error, most of which are preventable. Our goal is to describe these low-frequency events, and to provide guidelines for avoiding them. METHODS: The U.S. Food and Drug Administration (FDA) requires that all medical device manufacturers create a system for receiving, reviewing, and evaluating complaints (Code 21 of Federal Regulations 820.198). Silk Road Medical, Inc (Sunnyvale, Calif), has established a process by which all feedback, including complaints that may not meet FDA criteria, is captured and stored in a database for detailed analysis. More than 13,300 cases have been performed; submitted complaints were reviewed for incidents of serious injury and periprocedural complications, above and beyond the device-related events that must be reported to the FDA. RESULTS: A total of 13,334 patients have undergone TCAR worldwide between early 2011 and December 2019 using the SilkRoad device. Reported complications included 173 dissections (1.4% overall rate) of the common carotid artery at the access point, of which 22.5% were managed without intervention or with medical therapy alone and 24.3% were converted to CEA (considered failing safely). Errors in the location of stent deployment occurred in 16 cases (0.13%), with the most common site being the external carotid artery (75%). One wrong side carotid artery stent was placed in a patient with a high midline pattern of the bovine arch. Cranial nerve injury was reported in 11 cases (0.08%), only one of which persisted beyond 3 months. There have been three reported pneumothoraces and one reported chylothorax. Many of these errors can be recognized and prevented with careful attention to detail. CONCLUSIONS: In high-risk patients requiring treatment for carotid artery stenosis, TCAR has been proven as an alternative to TF-CAS with an excellent safety profile. As with CEA or TF-CAS, this procedure has the potential for infrequent complications, often as a result of user technical error. Although significant, these events can be avoided through a review of the collective experience to date and recognition of potential pitfalls, as we have described.

publication date

  • October 14, 2020

Research

keywords

  • Carotid Stenosis
  • Endovascular Procedures
  • Medical Errors

Identity

Scopus Document Identifier

  • 85100120619

Digital Object Identifier (DOI)

  • 10.1016/j.jvs.2020.09.023

PubMed ID

  • 33065241

Additional Document Info

volume

  • 73

issue

  • 5