Surgical outcomes of dual-plate fixation for periprosthetic femur fractures around a stable hip arthroplasty stem. Academic Article uri icon

Overview

abstract

  • INTRODUCTION: The incidence of periprosthetic femur fractures is increasing. Multiple treatment methods exist to treat fractures surrounding stable hip arthroplasty implants including locking plate fixation, cable fixation, allograft augmentation, and revision arthroplasty. No consensus regarding optimal treatment has been reached, and significant complications remain. Recently, biomechanical studies have demonstrated the benefits of orthogonal dual-plate fixation, but little clinical data exist. The purpose of the current study was to investigate the clinical and radiographic outcomes of dual-plated periprosthetic femur fractures around stable hip stems. MATERIALS AND METHODS: Patients with periprosthetic femur fractures following hip arthroplasty with a stable femoral stem treated with dual-plate fixation were identified through chart review at a single institution. Fracture classification, fixation characteristics, radiographic outcomes, clinical outcomes and complications including re-operation were recorded. RESULTS: Over a 12-year period, 31 patients (mean age 77 years at surgery, range 48-94) underwent dual plating by three traumatologists for implant-stable periprosthetic femur fractures surrounding a hip arthroplasty stem. There were 27 Vancouver B1-type and 9 inter-prosthetic fractures. Average follow-up was 2 years. Of the 26 patients with minimum 6-month follow-up, 24 (92%) united after index surgery (mean time to union 6.0 months, range 1.5-14.0). Mean time to full weight-bearing post-operatively was 2.6 months (range 1.5-4.0 months). Two patients required secondary surgery to address nonunion. CONCLUSIONS: Dual-plating achieved high union rates with an acceptable complication profile for the treatment of periprosthetic femur fractures surrounding a stable hip arthroplasty stem. Our preferred fixation construct involves a lateral plate spanning the entire femur secured with non-locking bicortical screws supplemented with an anteriorly based reconstruction plate. Additional prospective research is required to confirm the results of this study.

publication date

  • May 18, 2021

Research

keywords

  • Arthroplasty, Replacement, Hip
  • Femoral Fractures
  • Periprosthetic Fractures

Identity

Scopus Document Identifier

  • 85106259748

Digital Object Identifier (DOI)

  • 10.1007/s00402-021-03950-9

PubMed ID

  • 34003368

Additional Document Info

volume

  • 142

issue

  • 12