Noise Reduction in Material Decomposition for Low-Dose Dual-Energy Cone-Beam CT. Academic Article uri icon

Overview

abstract

  • PURPOSE: Dual-energy cone-beam CT (DE-CBCT) is an emerging technology with potential application in diagnostic imaging and image-guided interventions. This paper reports DE-CBCT feasibility and investigates decomposition algorithms for maximizing low-dose performance for reconstruction-based DE decomposition. A framework of binary decision theory is used to examine the accuracy of DE decompositions obtained from analytical reconstructions of differentially filtered low-energy (LE) and high-energy (HE) data and from penalized likelihood (PL) reconstructions with differential regularization using quadratic and total variation penalties. METHODS: Accurate DE-CBCT decomposition benefits from consideration of all system noise components. Filtered backprojection (FBP) reconstruction-based decomposition was investigated with differential filtering of LE and HE data. Penalized likelihood reconstruction-based decomposition with differential regularization was hypothesized to further improve low-dose performance, especially when coupled with regularization through a total variation edge preserving penalty that encourages piecewise smooth images. Performance of decomposition was assessed in terms of a binary hypothesis framework of sensitivity, specificity, and accuracy. Studies involved experiments on a DE-CBCT testbench, phantoms of variable material type and concentration, and cadavers (knee arthrography). RESULTS: Studies support the overall feasibility of accurate, low-dose DE-CBCT at concentration down to 5 mg/ml (iodine), dose ~3-6 mGy, and accuracy of material classification ~90%. Reconstruction-based decomposition with quadratic PL performed comparably to FBP. PL with a total variation penalty provided edge preservation and piecewise smooth images that aided DE classification and achieved improved performance over FBP and quadratic PL, reaching accuracy of ~0.98 for 2 mg/mL iodine at 3.2 mGy, compared to approx. 0.9 for FBP and quadratic PL. CONCLUSIONS: Accurate material decomposition with DE-CBCT is feasible at low dose and benefits from a rigorous assessment of noise mechanisms among various reconstruction-based techniques. The work points to the potential for non-linear iterative reconstruction methods for high-quality decomposition at low material concentration and dose.

publication date

  • March 21, 2013

Identity

PubMed Central ID

  • PMC8238468

Scopus Document Identifier

  • 84878293587

Digital Object Identifier (DOI)

  • 10.1117/12.2008431

PubMed ID

  • 34188351

Additional Document Info

volume

  • 8668