Is There a Difference in Screw Accuracy, Robot Time Per Screw, Robot Abandonment, and Radiation Exposure Between the Mazor X and the Renaissance? A Propensity-Matched Analysis of 1179 Robot-Assisted Screws. Academic Article uri icon

Overview

abstract

  • STUDY DESIGN: Prospective single-cohort analysis. OBJECTIVES: To compare the outcomes/complications of 2 robotic systems for spine surgery. METHODS: Adult patients (≥18-years-old) who underwent robot-assisted spine surgery from 2016-2019 were assessed. A propensity score matching (PSM) algorithm was used to match Mazor X to Renaissance cases. Preoperative CT scan for planning and an intraoperative O-arm for screw evaluation were preformed. Outcomes included screw accuracy, robot time/screw, robot abandonment, and radiation. Screw accuracy was measured using Vitrea Core software by 2 orthopedic surgeons. Screw breach was measured according to the Gertzbein/Robbins classification. RESULTS: After PSA, a total of 65 patients (Renaissance: 22 vs. X: 43) were included. Patient/operative factors were similar between robot systems (P > .05). The pedicle screw accuracy was similar between robots (Renaissance: 1.1%% vs. X: 1.3%, P = .786); however, the S2AI screw breach rate was significantly lower for the X (Renaissance: 9.5% vs. X: 1.2%, P = .025). Robot time per screw was not statistically different (Renaissance: 4.6 minutes vs. X: 3.9 minutes, P = .246). The X was more reliable with an abandonment rate of 2.3% vs. Renaissance:22.7%, P = .007. Radiation exposure were not different between robot systems. Non-robot related complications including dural tear, loss of motor/sensory function, and blood transfusion were similar between robot systems. CONCLUSION: This is the first comparative analyses of screw accuracy, robot time/screw, robot abandonment, and radiation exposure between the Mazor X and Renaissance systems. There are substantial improvements in the X robot, particularly in the perioperative planning processes, which likely contribute to the X's superiority in S2AI screw accuracy by nearly 8-fold and robot reliability by nearly 10-fold.

authors

  • Lee, Nathan
  • Zuckerman, Scott L
  • Buchanan, Ian A
  • Boddapati, Venkat
  • Mathew, Justin
  • Marciano, Gerard
  • Robertson, Djani
  • Lakomkin, Nikita
  • Park, Paul
  • Leung, Eric
  • Lombardi, Joseph M
  • Lehman, Ronald A

publication date

  • July 8, 2021

Identity

Scopus Document Identifier

  • 85109403261

Digital Object Identifier (DOI)

  • 10.1177/21925682211029867

PubMed ID

  • 34235996

Additional Document Info