Do Metaphyseal Cones and Stems Provide Any Biomechanical Advantage for Moderate Contained Tibial Defects in Revision TKA? A Finite-Element Analysis Based on a Cadaver Model. Academic Article uri icon

Overview

abstract

  • BACKGROUND: Satisfactory management of bone defects is important to achieve an adequate reconstruction in revision TKA. Metaphyseal cones to address such defects in the proximal tibia are increasingly being used; however, the biomechanical superiority of cones over traditional techniques like fully cementing the implant into the defect has not yet been demonstrated. Moreover, although long stems are often used to bypass the defects, the biomechanical efficacy of long stems compared with short, cemented stems when combined with metaphyseal cones remains unclear. QUESTIONS/PURPOSES: We developed and validated finite-element models of nine cadaveric specimens to determine: (1) whether using cones for addressing moderate metaphyseal tibial defects in revision TKA reduces the risk of implant-cement debonding compared with cementing the implant alone, and (2) when using metaphyseal cones, whether long, uncemented stems (or diaphyseal-engaging stems) reduce the risk of implant-cement debonding and the cone-bone micromotions compared with short, cemented stems. METHODS: We divided nine cadaveric specimens (six male, three female, aged 57 to 73 years, BMI 24 to 47 kg/m2) with standardized tibial metaphyseal defects into three study groups: no cone with short (50-mm) cemented stem, in which the defect was filled with cement; cone with short (50-mm) cemented stem, in which a metaphyseal cone was implanted before cementing the implant; and cone with long, diaphyseal-engaging stem, which received a metaphyseal cone and the largest 150-mm stem that could fit the diaphyseal canal. The specimens were implanted and mechanically tested. Then, we developed and validated finite-element models to investigate the interaction between the implant and the bone during the demanding activity of stair ascent. We quantified the risk of implant debonding from the cement mantle by comparing the axial and shear stress at the cement-implant interface against an experimentally derived interface failure index criterion that has been previously used to quantify the risk of cement debonding. We considered the risk of debonding to be minimal when the failure index was below 10% of the strength of the interface (or failure index < 0.1). We also quantified the micromotion between the cone and the bone, as a guide to the likelihood of fixation by bone ingrowth. To this end, we assumed bone ingrowth for micromotion values below the most restrictive reported threshold for bone ingrowth, 20 µm. RESULTS: When using a short, 50-mm cemented stem and cement alone to fill the defect, 77% to 86% of the cement-implant interface had minimal risk of debonding (failure index < 0.1). When using a short, 50-mm cemented stem with a cone, 87% to 93% of the cement-implant interface had minimal debonding risk. When combining a cone with a long (150-mm) uncemented stem, 92% to 94% of the cement-implant interface had minimal debonding risk. The differences in cone-bone micromotion between short, cemented stems and long, uncemented stems were minimal and, for both configurations, most cones had micromotions below the most restrictive 20-µm threshold for ingrowth. However, the maximum micromotion between the cone and the bone was in general smaller when using a long, uncemented stem (13-23 µm) than when using a short, cemented stem (11-31 µm). CONCLUSION: Although the risk of debonding was low in all cases, metaphyseal cones help reduce the biomechanical burden on the implant-cement interface of short-stemmed implants in high-demand activities such as stair ascent. When using cones in revision TKA, long, diaphyseal-engaging stems did not provide a clear biomechanical advantage over short stems. Future studies should explore additional loading conditions, quantify the interspecimen variability, consider more critical defects, and evaluate the behavior of the reconstructive techniques under repetitive loads. CLINICAL RELEVANCE: Cones and stems are routinely used to address tibial defects in revision TKA. Despite our finding that metaphyseal cones may help reduce the risk of implant-cement debonding and allow using shorter stems with comparable biomechanical behavior to longer stems, either cones or cement alone can provide comparable results in contained metaphyseal defects. However, longer term clinical studies are needed to compare these techniques over time.

publication date

  • November 1, 2021

Research

keywords

  • Arthroplasty, Replacement, Knee
  • Bone Cements
  • Bone-Implant Interface
  • Knee Prosthesis
  • Tibia

Identity

PubMed Central ID

  • PMC8509913

Scopus Document Identifier

  • 85120527280

Digital Object Identifier (DOI)

  • 10.1097/CORR.0000000000001912

PubMed ID

  • 34351312

Additional Document Info

volume

  • 479

issue

  • 11