The Use of a Transforaminal Lumbar Interbody Fusion (TLIF) Cage Following Inadequate Access to the Disc Space During an Anterior Lumbar Interbody Fusion Procedure. uri icon

Overview

abstract

  • Non-specific lower back pain caused by degenerative lumbar disease, such as disc and facet joint degeneration or spondylolisthesis, significantly impairs quality of life of patients and is associated with higher pain scores and reduced function. Patients that fail to respond to conservative treatment may require surgical intervention, such as lumbar interbody fusion (LIF). Compared to other approaches, an anterior approach to lumbar interbody fusion (ALIF) has advantages regarding efficacy of fusion, visualization of relevant anatomy, and a larger allowable size of the interbody fusion device. An anterior approach's main biomechanical advantage includes the ability to restore sagittal alignment, achieve indirect decompression, and provide increased anterior column support. Complications of anterior interbody fusion are mostly approach related and include vascular injury or visceral injury. However, the anterior anatomy can make the placement of an interbody device challenging. In the case reported here, an ALIF procedure was complicated by immobile iliac vessels leaving a small window to place the interbody cage. Continuing with the anterior approach was opted, but with the oblique placement of a cage traditionally used in transforaminal lumbar interbody fusion (TLIF) procedures.

publication date

  • March 3, 2022

Identity

PubMed Central ID

  • PMC8976413

Digital Object Identifier (DOI)

  • 10.7759/cureus.22792

PubMed ID

  • 35382207

Additional Document Info

volume

  • 14

issue

  • 3