Percutaneous Juxtapedicular Cement Salvage of Failed Spinal Instrumentation? Institutional Experience and Cadaveric Biomechanical Study. Academic Article uri icon

Overview

abstract

  • BACKGROUND AND OBJECTIVES: Instrumented spinal fusion constructs sometimes fail because of fatigue loading, frequently necessitating open revision surgery. Favorable outcomes after percutaneous juxtapedicular cement salvage (perc-cement salvage) of failing instrumentation have been described; however, this approach is not widely known among spine surgeons , and its biomechanical properties have not been evaluated. We report our institutional experience with perc-cement salvage and investigate the relative biomechanical strength of this technique as compared with 3 other common open revision techniques. METHODS: A retrospective chart review of patients who underwent perc-cement salvage was conducted. Biomechanical characterization of revision techniques was performed in a cadaveric model of critical pedicle screw failure. Three revision cohorts involved removal and replacement of hardware: (1) screw upsizing, (2) vertebroplasty, and (3) fenestrated screw with cement augmentation. These were compared with a cohort with perc-cement salvage performed using a juxtapedicular trajectory with the failed primary screw remaining engaged in the vertebral body. RESULTS: Ten patients underwent perc-cement salvage from 2018 to 2022 to address screw haloing and/or endplate fracture threatening construct integrity. Pain palliation was reported by 8/10 patients. Open revision surgery was required in 4/10 patients, an average of 8.9 months after the salvage procedure (range 6.2-14.7 months). Only one revision was due to progressive hardware dislodgement. The remainder avoided open revision surgery through an average of 1.9 years of follow-up. In the cadaveric study, there were no significant differences in pedicle screw pullout strength among any of the revision cohorts. CONCLUSION: Perc-cement salvage of failing instrumentation is reasonably efficacious. The technique is biomechanically noninferior to other revision strategies that require open surgery for removal and replacement of hardware. Open revision surgery may be avoided by perc-cement salvage in select cases.

publication date

  • September 25, 2023

Research

keywords

  • Lumbar Vertebrae
  • Pedicle Screws

Identity

Scopus Document Identifier

  • 85180004893

Digital Object Identifier (DOI)

  • 10.1227/ons.0000000000000924

PubMed ID

  • 37747337

Additional Document Info

volume

  • 26

issue

  • 1