Practical approach to confirm femoral artery patency after percutaneous closure for veno-arterial extracorporeal membrane oxygenation decannulation. Academic Article uri icon

Overview

abstract

  • BACKGROUND: We describe a technique to assess blood flow distal to the decannulation site after deployment of Perclose ProGlide (Abbott Vascular, Abbott Park, Ill) in patients on femoral veno-arterial extracorporeal membrane oxygenation (VA-ECMO) support. TECHNIQUE: An antegrade distal perfusion catheter was placed in all patients, and decannulation was primarily performed at bedside (N = 11/12). With the VA-ECMO circuit switched off, a needle was inserted into the arterial tubing, passed through the femoral arterial cannula into the artery. The arterial cannula was removed over a wire and the previously placed Proglide Perclose sutures were secured. Back bleeding from the antegrade distal perfusion catheter, confirmed using a three-way connector, indicated blood flow to the superficial femoral artery. This was followed by confirmation of blood flow to the lower leg using a Doppler ultrasound. Hemostasis of the antegrade perfusion catheter was achieved through manual compression. RESULTS: We implemented this technique in 12 patients with a technical success rate of 100%. There were no ipsilateral leg ischemia, bleeding, pseudoaneurysm, or infection after decannulation. CONCLUSIONS: This technique allows prompt assessment of blood flow to the distal leg immediately following arterial decannulation.

publication date

  • December 2, 2023

Research

keywords

  • Extracorporeal Membrane Oxygenation
  • Femoral Artery

Identity

Digital Object Identifier (DOI)

  • 10.1177/02676591231220820

PubMed ID

  • 38041692