Interest in the new thromboelastometry device, Clot Pro®, for predicting thrombocytopenia and hypofibrinogenemia during lung transplantation.
Academic Article
Overview
abstract
INTRODUCTION: Lung transplantation is associated with high proportion of transfusion. Monitoring of coagulopathy using viscoelastic tests could aid in the perioperative management of bleeding. The aim of the study was to assess the predictive cut-off values for thrombocytopenia and hypofibrinogenemia using the new thromboelastography analyzer, ClotPro. METHODS: We retrospectively enrolled 65 patients who underwent lung transplantation and were sampled for both viscoelastic assays and conventional coagulation assays simultaneously during the procedure. We characterized the correlation between the EX-test (extrinsic pathway) and platelet count as well as between the FIB-test (extrinsic pathway after platelet inhibition) and fibrinogen concentration. Then, we used ROC curve analysis to determine the optimal EX-test and FIB-test values for predicting thrombocytopenia and hypofibrinogenemia. RESULTS: All the amplitude values of the EX-test (A5, A10, A20, MCF) showed correlation with platelets count (Spearman's rank correlation coefficient ranging from 0.75 to 0.77, all p < 0.0001). We also observed a strong correlation between the amplitude values of the FIB-test (A5, A10, A20 and MCF) and the fibrinogen concentration (Spearman's rank correlation coefficient ranging from 0.68 to 0.71, all p < 0.0001). The AUCs of the EX-test values for thrombocytopenia <100 G/L and <80 G/L ranged from 0.80 to 0.93. Similarly, the AUCs of the FIB-test values for hypofibrinogenemia <1.5 g/L and <2 g/L ranged from 0.74 to 0.83. These results indicate that only the five-minute parameter of thromboelastometry is sufficient for detecting thrombocytopenia and hypofibrinogenemia in patients undergoing lung transplantation. The proposed cut off values for the EX-test to predict thrombocytopenia <80 G/L showed high sensitivity (>86 %), high specificity (>89 %) and high negative predictive value (>95 %). FIB-test cut off values predictive of fibrinogen below 1.5 g/L showed sensitivity (>78 %), specificity (>55 %) and negative predictive value (>88 %). CONCLUSIONS: Our study provided preliminary results that are useful for developing a ClotPro-based algorithm to guide transfusion in lung transplantation. Future interventional studies will be necessary to validate these cut-off values of ClotPro for guiding transfusion.