Reliability assessment of the OMERACT whole-body magnetic resonance imaging scoring system for juvenile idiopathic arthritis. Academic Article uri icon

Overview

abstract

  • Inter-reader reliability of a new scoring system for evaluating joint inflammation and enthesitis in whole body MRI (WBMRI) in juvenile idiopathic arthritis was tested. The scoring system grades 732 item-region combinations of bone marrow and soft tissue changes for commonly involved joints and entheseal sites. Five radiologists rated 17 WBMRI scans through an online rating platform. Item-wise reliability was calculated for 117 items with non-zero scores in >10 % of readings. Interquartile ranges of the five-reader Kappa reliability coefficients were 0.58-0.73 (range: 0.36-0.88) for the joints, 0.65-0.81 (range: 0.39-0.95) for the entheses, and 0.62-0.75 (range: 0.60-0.76) for chronic nonbacterial osteomyelitis-like lesions.

publication date

  • March 16, 2024

Research

keywords

  • Arthritis, Juvenile
  • Magnetic Resonance Imaging
  • Whole Body Imaging

Identity

PubMed Central ID

  • PMC11134403

Scopus Document Identifier

  • 85189333320

Digital Object Identifier (DOI)

  • 10.1016/j.semarthrit.2024.152437

PubMed ID

  • 38564998

Additional Document Info

volume

  • 66