Atrioventricular Synchrony Delivered by a Dual-Chamber Leadless Pacemaker System. Academic Article uri icon

Overview

abstract

  • BACKGROUND: A dual-chamber leadless pacemaker system has been designed for AV synchronous pacing using wireless, beat-to-beat, implant-to-implant (i2i) communication between distinct atrial and ventricular leadless pacemakers. The AV synchrony achieved across various ambulatory scenarios has yet to be systematically evaluated. METHODS: A prospective, single-arm, unblinded, multicenter, international clinical trial of the leadless pacemaker system was conducted in patients with a conventional dual-chamber pacing indication enrolled from February 2022 to March 2023. Leadless pacemaker systems were implanted, and 12-lead Holter electrocardiographic recordings were collected 3 months after implantation over various postures/activities: sitting, supine, left lateral recumbent, right lateral recumbent, standing, normal walk, and fast walk. An independent Holter core laboratory performed a manual adjudication of the percent of AV synchronous beats using the standard 300-millisecond PR interval limit. Atrium-to-ventricle and ventricle-to-atrium i2i communication success rates were also assessed. Post hoc summary statistics describing the relationships between AV synchrony and i2i success, posture/activity, implantation indication, AV event, and heart rate were calculated. RESULTS: In the evaluable population (n=384 of 464 enrolled [83%]; 61% male; age, 70 years; weight, 82 kg; 60% ejection fraction; 95% of beats evaluable), the mean AV synchrony of 98% of beats observed across all postures using the standard 300-millisecond limit was greater than both atrium-to-ventricle i2i (94%) and ventricle-to-atrium i2i (94%; P<0.001), exceeding both i2i values in 95% of patients. AV synchrony was achieved in >95% of evaluable beats across all postures/activities, implantation indications, AV paced/sensed event combinations, and heart rate ranges (including >100 bpm). CONCLUSIONS: This dual-chamber leadless pacemaker system demonstrated AV synchrony in 98% of evaluable beats at 3 months after implantation. AV synchrony was maintained across postures/activities and remained robust for heart rates >100 bpm.

authors

  • Ip, James E.
  • Rashtian, Mayer
  • Exner, Derek V
  • Reddy, Vivek Y
  • Doshi, Rahul
  • Badie, Nima
  • Nevo, Jordan R
  • Goil, Aditya
  • Defaye, Pascal
  • Canby, Robert
  • Bongiorni, Maria Grazia
  • Shoda, Morio
  • Hindricks, Gerhard
  • Knops, Reinoud E

publication date

  • July 8, 2024

Research

keywords

  • Pacemaker, Artificial

Identity

Digital Object Identifier (DOI)

  • 10.1161/CIRCULATIONAHA.124.069006

PubMed ID

  • 38973458