Simulation of B0 magnetic field conditions in the human heart for improved diagnostic MRI. Academic Article uri icon

Overview

abstract

  • BACKGROUND: Cardiac balanced steady-state free precession (bSSFP) MRI suffers from dark band artifacts due to severe B0 inhomogeneity induced by air-tissue interfaces in the human body. Those artifacts remain uncontrollable despite scanner-provided B0 shimming based on low-order spherical harmonic shapes. To mitigate those artifacts for higher image fidelity, the development of advanced B0 shimming techniques is demanding and typically requires knowledge of cardiac B0 conditions across patient populations. We recently proposed a new simulation approach to derive cardiac B0 distributions from readily available chest-abdomen-pelvis CT structural images based on first principles of classical electrodynamics. This approach is able to calculate the air-tissue interface-induced magnetic field variation across the body from diverse subjects using regular CT images. While the computational method has been step-by-step validated in previous work, a comprehensive demonstration in patients has been missing. PURPOSE: The aim of this study is to validate our proposed structural CT-derived cardiac B0 magnetic field computation approach using a side-by-side comparison between simulation and in vivo measurement obtained from the same cohort of clinical subjects. METHODS: Six subjects (female: 3, male: 3, age: 54.5 ± 17.2 years) with aortic stenosis or cancer who underwent clinically-indicated CT scans of the chest, abdomen, and pelvis were consented to undergo additional in vivo cardiac B0 measurement on a 3T MRI scanner. B0 distributions in the heart were computed based on CT images using our recently proposed approach and in vivo B0 maps acquired experimentally. CT images and MRI-based anatomical images were co-registered before field calculation, followed by the side-by-side field comparison after computation using correlation analysis of inhomogeneous field values, as well as the comparison of first-order spherical harmonic coefficients after decomposing field maps and the residual B0 inhomogeneities after shim from first to fifth order. RESULTS: Simulated B0 maps show excellent agreement with in vivo measured B0 maps and strong average correlation (r = 0.92). After first and second-order shim analyses, both field maps show highly similar residual local B0 field patterns, especially near cardiophrenic angles and in the heart's inferior region, demonstrating the authenticity of localized features beyond overall field congruency. Both groups also demonstrate the trend of decreasing residual B0 inhomogeneity after shimming from first to fifth order, and their absolute differences in the mean of all subjects range from 0.25 to 2.3 Hz across different SH orders. CONCLUSIONS: The consistency between simulation and in vivo measurements of B0 field conditions in the human heart from patients exhibiting various cardiac conditions fully validates the established B0 simulation approach. This approach can accurately compute the air-tissue interface-induced inhomogeneous magnetic field shapes and amplitudes from readily available structural CT images, setting the stage for the development of tailored and advanced cardiac B0 magnetic field correction methods and more robust cardiac MRI.

authors

  • Shang, Yun
  • Theilenberg, Sebastian
  • Castillo, Michelle
  • Peng, Boyu
  • Fung, Maggie
  • Quarterman, Patrick
  • Navot, Benjamin
  • Jambawalikar, Sachin R
  • Einstein, Andrew J
  • Juchem, Christoph

publication date

  • February 19, 2026

Identity

Digital Object Identifier (DOI)

  • 10.1016/j.zemedi.2026.02.005

PubMed ID

  • 41720728