Subharmonic Response of Polymer Contrast Agents Based on the Empirical Mode Decomposition.
Academic Article
Overview
abstract
The subharmonic threshold for ultrasound contrast agents has been defined as a 20-25 dB difference between the fundamental and subharmonic (2/1) spectral components of the backscatter signal. However, this Fourier-based criterion assumes a linear time-invariant signal. A more appropriate criterion for short cycle and frequency-modulated waveforms is proposed with an adaptive signal-processing approach based on the empirical mode decomposition (EMD) method. The signal is decomposed into an orthogonal basis known as intrinsic mode functions (IMFs) and a subharmonic threshold is defined with respect to the energy ratio of the subharmonic IMF component to that of the incident signal. The method is applied to backscatter data acquired from two polymer-shelled contrast agents, Philips (#38, mean diameter 2.0 [Formula: see text]) and Point Biomedical (#12027, mean diameter 3.9 [Formula: see text]). The acoustic backscatter signals are investigated for a single contrast agent subjected to monofrequency (20 MHz, 20 cycles) and chirp (15-25 MHz, 20 cycles) forcing for incident pressures ranging from 0.5 to 2.4 MPa. In comparison to the spectral peak difference (20 dB) criterion, the EMD method is more sensitive in determining subharmonic signals.