Technical Note: Patient-morphed mesh-type phantoms to support personalized nuclear medicine dosimetry - a proof of concept study. Academic Article uri icon

Overview

abstract

  • PURPOSE: Current standard practice for clinical radionuclide dosimetry utilizes reference phantoms, where defined organ dimensions represent population averages for a given sex and age. Greater phantom personalization would support more accurate dose estimations and personalized dosimetry. Tailoring phantoms is traditionally accomplished using operator-intensive organ-level segmentation of anatomic images. Modern mesh phantoms provide enhanced anatomical realism, which has motivated their integration within Monte Carlo codes. Here, we present an automatable strategy for generating patient-specific phantoms/dosimetry using intensity-based deformable image registration between mesh reference phantoms and patient CT images. This work demonstrates a proof-of-concept personalized dosimetry workflow, presented in comparison to the manual segmentation approach. METHODS: A linear attenuation coefficient phantom was generated by resampling the PSRK-Man reference phantom onto a voxel grid and defining organ regions with corresponding Hounsfield unit (HU) reference values. The HU phantom was co-registered with a patient CT scan using Plastimatch B-spline deformable registration. In parallel, major organs were manually contoured to generate a "ground truth" patient-specific phantom for comparisons. Monte Carlo derived S-values, which support nuclear medicine dosimetry, were calculated using both approaches and compared. RESULTS: Application of the derived B-spline transform to the polygon vertices comprising the PSRK-Man yielded a deformed variant more closely matching the patient's body contour and most organ volumes as-evaluated by Hausdorff distance and Dice metrics. S-values computed for fluorine-18 for the deformed phantom using the Particle and Heavy Ion Transport code System showed improved agreement with those derived from the patient-specific analog. CONCLUSIONS: Deformable registration techniques can be used to create a personalized phantom and better support patient-specific dosimetry. This method is shown to be easier and faster than manual segmentation. Our study is limited to a proof-of-concept scope, but demonstrates that integration of personalized phantoms into clinical dosimetry workflows can reasonably be achieved when anatomical images (CT) are available.

publication date

  • March 9, 2021

Research

keywords

  • Nuclear Medicine

Identity

PubMed Central ID

  • PMC8058313

Scopus Document Identifier

  • 85102309546

Digital Object Identifier (DOI)

  • 10.1002/mp.14784

PubMed ID

  • 33595863

Additional Document Info

volume

  • 48

issue

  • 4