A Comparative Analysis of the Respiratory Subscore of the Sequential Organ Failure Assessment Scoring System. Academic Article uri icon

Overview

abstract

  • Rationale: The Sequential Organ Failure Assessment (SOFA) tool is a commonly used measure of illness severity. Calculation of the respiratory subscore of SOFA is frequently limited by missing arterial oxygen pressure (PaO2) data. Although missing PaO2 data are commonly replaced with normal values, the performance of different methods of substituting PaO2 for SOFA calculation is unclear. Objectives: The study objective was to compare the performance of different substitution strategies for missing PaO2 data for SOFA score calculation. Methods: This retrospective cohort study was performed using the Weill Cornell Critical Care Database for Advanced Research from a tertiary care hospital in the United States. All adult patients admitted to an intensive care unit (ICU) from 2011 to 2019 with an available respiratory SOFA score were included. We analyzed the availability of the PaO2/fraction of inspired oxygen (FiO2) ratio on the first day of ICU admission. In those without a PaO2/FiO2 ratio available, the ratio of oxygen saturation as measured by pulse oximetry to FiO2 was used to calculate a respiratory SOFA subscore according to four methods (linear substitution [Rice], nonlinear substitution [Severinghaus], modified respiratory SOFA, and multiple imputation by chained equations [MICE]) as well as the missing-as-normal technique. We then compared how well the different total SOFA scores discriminated in-hospital mortality. We performed several subgroup and sensitivity analyses. Results: We identified 35,260 unique visits, of which 9,172 included predominant respiratory failure. PaO2 data were available for 14,939 (47%). The area under the receiver operating characteristic curve for each substitution technique for discriminating in-hospital mortality was higher than that for the missing-as-normal technique (0.78 [0.77-0.79]) in all analyses (modified, 0.80 [0.79-0.81]; Rice, 0.80 [0.79-0.81]; Severinghaus, 0.80 [0.79-0.81]; and MICE, 0.80 [0.79-0.81]) (P < 0.01). Each substitution method had a higher accuracy for discriminating in-hospital mortality (MICE, 0.67; Rice, 0.67; modified, 0.66; and Severinghaus, 0.66) than the missing-as-normal technique. Model calibration for in-hospital mortality was less precise for the missing-as-normal technique than for the other substitution techniques at the lower range of SOFA and among the subgroups. Conclusions: Using physiologic and statistical substitution methods improved the total SOFA score's ability to discriminate mortality compared with the missing-as-normal technique. Treating missing data as normal may result in underreporting the severity of illness compared with using substitution. The simplicity of a direct oxygen saturation as measured by pulse oximetry/FiO2 ratio-modified SOFA technique makes it an attractive choice for electronic health record-based research. This knowledge can inform comparisons of severity of illness across studies that used different techniques.

publication date

  • November 1, 2021

Research

keywords

  • Organ Dysfunction Scores
  • Oximetry

Identity

PubMed Central ID

  • PMC8641830

Scopus Document Identifier

  • 85118480478

Digital Object Identifier (DOI)

  • 10.1001/jama.2021.1545

PubMed ID

  • 33760709

Additional Document Info

volume

  • 18

issue

  • 11